Flow Cytometry and Cell Sorting (FCCS)
The Flow Cytometry and Cell Sorting (FCCS) Core provides state-of-the-art instruments, expertise, instruction, and assistance with experimental design and data analysis for multicolor flow cytometry and cell sorting experiments, including indexed single-cell sorting.
We offer one-on-one consultation with internal investigators at no charge for experimental design, training in the use of the instrumentation (hourly rate), software resources and data analysis (hourly rate).
|
Molecular Sciences Building (858 Madison), Room 214
|
Mon-Fri, 9:00am-5:00pm; after hours by appointment only
|
EQUIPMENT
THE CYTEK AURORA CS
The CS spectral cell sorter uses five lasers to detect up to 64 fluorescence parameters, capturing the full fluorochrome spectrum to enable larger (40+) marker panlels and the simultaneous use of more fluorophores that would otherwise be incompatible. The five lasers include a 350nm laser (UV) with 16 detectors, 405nm laser (violet) with 16 detectors, 488nm laser (blue) with 14 detectors, 561nm laser (yellow-green) with 10 detectors and 640nm laser (red) with 8 detectors. It has three scatter detectors (FSC, SSC, 405 SSC) and 2 sets of 4 interchangeable nozzle sizes (70, 85, 100 and 130 um) for flexible, high speed sorting. The Cytek Aurora CS is capable of 2-way sorting into 15ml tubes, 4- and 6-way sorting into 1.5 and 5 mL tubes, single cell sorting into 96-well plates, and index sorting. It runs SpectroFlo software with user-friendly guided workflows. Users can create a free Cytek Cloud account to design panels and experimental templates, which can then be imported into the Cytek Aurora CS.
THE BIO-RAD ZE5 CELL ANALYZER
The ZE5 is equipped with 4 lasers capable of detecting up to 21-fluorescence parameters. The lasers include a 405nm laser with 7 fluorescence detectors, and a small particle FSC detector, a 100mW, 488 nm laser with 5 fluorescence, SSC, and FSC detectors, a 50 mW 561 nm laser with seven fluorescence detectors, and a 100 mW, 640 nm laser with three fluorescence detectors. The instrument also has the capability for small particle detection (exosomes, subcellular particles, and bacteria) and offers operator-independent programmable sample loading and data collection for up to 48 tubes and 96 well plates. The “Everest” software is more user-friendly than traditional flow cytometry software platforms.
Also available for use at no additional charge are Ƿɴ® and Ѵǻ® software on workstations for advanced data analysis and cell cycle modeling.
STAFF

Elizabeth Fitzpatrick, PhD
Interim Core Director
901.448.5405
efitzpat@uthsc.edu

Suman Kundu, PhD
Flow Cytometry Specialist
901.448.4279
skundu1@uthsc.edu


